Intensive-Care Ventilator KIV-A200

Intensive-Care Ventilator KIV-A200

Intensive-Care Ventilator KIV-A100 is a high performance, closed-loop controlled, pneumatically-driven critical care ventilator with multiple ventilation modes. System features high resolution detachable touch screen with navigation knob to view monitored parameters, pulmonary mechanics waveform, lung volumes, flow-volume loops and three-level audio-visual alarm system with 360-degree panoramic alert light.

Download Catalog
Tidal Volume 20 ml ─ 2500 ml
Configurations Trolley or Ceiling Pendant
Respiratory Rate 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV)
4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
P<sub>support</sub> 0 kPa ─ 6 kPa
P<sub>control</sub> 0.5 kPa ─ 6 kPa
Pulmonary Mechanics Waveform 3
Loops 2
Standard Ventilation Modes VCV (A/C)
PCV (A/C)
SIMV (VCV)
SIMV(PCV)
SIMV (PRVC)
SPONT/CPAP
NIV/CPAP
NIV/PCV
BIVENT
Combined Ventilation Modes SPONT+PS
SIMV(VCV)+ PS
SIMV(PCV)+PS
SIMS(PRVC)+PS
BIVENT+PS
VCV+SIGH
NIV/CPAP+PS
Inspiration Time 0.1 s ─ 12 s
Inspiratory Pause Time 0 s ─ 4 s
FiO<sub>2</sub> Range 21% ─ 100%
Trigger Sensitivity Pressure : - 2 kPa to 0 kPa (above PEEP)
Flow : 0.5 LPM ─ 20 LPM (base flow)
PEEP 0 kPa ─ 5 kPa
Suction < 2 min
Nebulizer 30 mins
Pressure Values Pplat / Ppeak / Pmean / PEEP
Volume / Flow values VTI / VTE / MV / MVspont
Time Values Ftotal / Fspont / I : E
Oxygen Monitoring Without O2 sensor ( O2 sensor optional )
Gas Supply O2, Air (0.28 MPa – 6 MPa)
Real-time Curves Pressure-Time
Flow-Time
Volume-Time
Pressure-Volume loop
Flow-Volume loop
Alarm Upper and Lower limits : MV, Paw, PEEP, Airway Pressure continuous high, VTE, Fspont high
Other Conditions : Tapnea, ,Power Fail, Nebulizer, Battery low, Battery exhausted, Air supply failure, O2 supply failure, Air and O2 supply failure, Fan block, Pipe block, Circuit disconnected
Display 12.1” TFT LCD touch screen
Internal Battery > 1 hour
Maximum Security Pressure ≤ 8 kPa
Compliance ≤ 4 ml / 100 Pa
Noise ≤ 65 dB (A)
Communication RS232, VGA, Nurse Call
Operational Temperature 5 °C to 40 °C
Relative Humidity ≤ 90 % (non-condensing)
Atmospheric Pressure 50 kPa – 106 kPa
Power Supply 110 V – 240 V (50 Hz / 60 Hz), 65 VA
Dimensions 328 x 410 x 410 mm
Weight 20 Kgs
  • Pneumatic-driven Flow Multiple Ventilation modes with BIVENT and PRVC Modes Invasive and Non-invasive Modes Flexible Configuration 15 Display Parameters Alarm Recording Feature Lung mechanics function monitoring

Used in operating rooms, surgical care wards, intensive care unit, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.

Used in operating rooms, surgical care wards, intensive care unit, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.

Infant Incubator

Infant Incubator KII-A101

Infant Incubator KII-A101

Control SystemAir-temp control & Skin-temp control'

DisplayLED display'

Catalog
Infant Incubator KII-A100

Infant Incubator KII-A100

Control SystemAir-temp control, Skin-temp control & Humidity control'

DisplayLED display'

Catalog
Infant Incubator KII-A102
Infant Incubator KII-A102

Control SystemAir-temp control'

DisplayLED display'

Catalog

Infant Warmer

Infant Warmer KIW-A100

Infant Warmer KIW-A100

Control SystemMicroprocessor based temperature control system'

Control ModesPreheat, Manual and Skin-temp mode'

Catalog

Phototherapy Unit

LED Phototherapy System KPT-A100

LED Phototherapy System KPT-A100

Light Source8 Blue LED lights'

Wavelength450 to 475nm'

Catalog

Defibrillator

Automated External Defibrillator KED-A100

Automated External Defibrillator KED-A100

WaveformBiphasic'

Energy Sequence150 J, 200 J'

Catalog
Defibrillator Monitor KDM-A100

Defibrillator Monitor KDM-A100

Display7-inch screen'

WaveformBiphasic'

Catalog

Infusion Pump

Infusion Pump KIP–A101

Infusion Pump KIP–A101

ChannelSingle channel infusion'

Infusion Volume0 ml ~ 9999 ml ( 0.1ml increment)'

Catalog
Infusion Pump KIP–A100

Infusion Pump KIP–A100

ChannelSingle channel infusion'

Volume (VTBI)1 ml ~ 9999.9 ml ( 0.1 ml increment)'

Catalog

Syringe Pump

Syringe pump KSP–B100

Syringe pump KSP–B100

ChannelDual channel infusion'

Volume (VTBI)0.1 ml – 1999.9 ml'

Catalog
Syringe pump KSP-A100

Syringe pump KSP-A100

KVO Rate0.1 – 5ml/h (steps : 0.1ml/h)'

Injection ComplianceAdaptable for 5 syringe sizes'

Catalog
Syringe pump KSP–A200
Syringe pump KSP–A200

ChannelSingle channel infusion'

Volume (VTBI)0 ml – 9999 ml'

Catalog

Blood and Infusion Warmer

Blood and Infusion Warmer KBIW-A100

Blood and Infusion Warmer KBIW-A100

Temperature Range37°C to 42°C'

Temperature Accuracy± 0.5°C'

Catalog
Blood and Infusion Warmer KBIW-A200

Blood and Infusion Warmer KBIW-A200

Temperature Range37°C to 42°C'

Temperature Accuracy± 1.0°C'

Catalog

Resuscitator

Resuscitator KRE-A100

Resuscitator KRE-A100

TypeAdult'

Stroke volume800 ml'

Catalog
Resuscitator KRE-A102

Resuscitator KRE-A102

TypeNeonatal'

Stroke volume150 ml'

Catalog
Resuscitator KRE-A101
Resuscitator KRE-A101

TypePediatric'

Stroke volume350 ml'

Catalog