Syringe pump KSP–A100 is a light weight, portable device designed for low-volume infusion. Equipped with LCD screen to display parameters like injection state, volume, mode, speed, syringe size, alarms, dosage, occlusion status, etc. for enhanced clinical efficiency. Inbuilt software based control system delivers higher levels of precision, safety and allows remote control mechanism to improve standardization, accuracy analysis of infusion data and reduce free–flow risks.
| KVO Rate | 0.1 – 5ml/h (steps : 0.1ml/h) |
| Injection Compliance | Adaptable for 5 syringe sizes |
| Preset Volume Range | 0.1 ml – 1999.9 ml |
| Occlusion System | 3-level alarming system |
| Mechanical Precision | ≤ ±2 % |
| Injection Rate Range |
{"50 ml Syringe":"0.1 ml \u2013 999.9 ml\/h (step: 0.1 ml\/h) 1000 ml \u2013 1800 ml\/h (step: 1 ml\/h)","30 ml Syringe":"0.1 ml \u2013 900 ml\/h (step: 0.1 ml\/h)","20 ml Syringe":"0.1 ml \u2013 600 ml\/h (step: 0.1 ml\/h)","10 ml Syringe":"0.1 ml \u2013 300 ml\/h (step: 0.1 ml\/h)","5 ml Syringe":"0.1 ml \u2013 150 ml\/h (step: 0.1 ml\/h)"} |
| Purge Rate | {"50 ml Syringe":"1800 ml\/h (Bolus rate: 1200 ml\/h)","30 ml Syringe":"900 ml\/h (Bolus rate: 600 ml\/h)","20 ml Syringe":"600 ml\/h (Bolus rate: 400 ml\/h)","10 ml Syringe":"300 ml\/h (Bolus rate: 200 ml\/h)","5 ml Syringe":"150 ml\/h (Bolus rate: 100 ml\/h)"} |
| Occlusion Alarm Threshold | {"High":"800 mmHg \u00b1 200 mmHg (106.7 kPa \u00b1 26.7 kPa)","Medium":"500 mmHg \u00b1 100 mmHg (66.7 kPa \u00b1 13.3 kPa)","Low":"300 mmHg \u00b1 100 mmHg (40.7 kPa \u00b1 13.3 kPa)"} |
| Fuse | F1AL/250V (2 nos.) |
| Power Supply | 100 V – 220 V, 50 Hz |
| Battery | Built–in Rechargeable Li–ion battery (11.1V) Capacity ≥ 2000mAh ; 10 hours of charging Works at 5ml/h after 4 hours of charging |
| Alarm | Near Injection finished, Preset dose injection finished, Occlusion, Syringe off, Syringe dislocated, Low Battery, On AC Supply. |
| Safety | Class I Type BF |
| Operation | {"Ambient Temperature":"5\u00b0C to 40\u00b0C","Relative Humidity":"20% \u2013 90%","Atmospheric Pressure":"86 kPa \u2013 106 kPa"} |
| Storage | {"Ambient Temperature":"\u201330\u00b0C to 55\u00b0C","Relative Humidity":"\u2264 95%","Atmospheric Pressure":"50 kPa \u2013 106 kPa"} |
| Dimensions | 282 x 210 x 148 mm |
| Weight | 2 Kgs |
Used in general ward, ICU or post-operative care facilities in hospitals to gradually administer intravenous fluid drug dosage in controlled amounts at a predetermined rate and speed through syringe attached with a catheter for consistent and effective infusion therapy.
Used in general ward, ICU or post-operative care facilities in hospitals to gradually administer intravenous fluid drug dosage in controlled amounts at a predetermined rate and speed through syringe attached with a catheter for consistent and effective infusion therapy.
Control SystemAir-temp control'
DisplayLED display'
Control SystemAir-temp control & Skin-temp control'
DisplayLED display'
Control SystemAir-temp control, Skin-temp control & Humidity control'
DisplayLED display'
Control SystemMicroprocessor based temperature control system'
Control ModesPreheat, Manual and Skin-temp mode'
Light Source8 Blue LED lights'
Wavelength450 to 475nm'
Display7-inch screen'
WaveformBiphasic'
WaveformBiphasic'
Energy Sequence150 J, 200 J'
ChannelSingle channel infusion'
Volume (VTBI)1 ml ~ 9999.9 ml ( 0.1 ml increment)'
ChannelSingle channel infusion'
Infusion Volume0 ml ~ 9999 ml ( 0.1ml increment)'
Tidal Volume20 ml ~ 500 ml'
Standard Ventilation ModeVCV, SIMV, PSV, PCV, CPAP, Manual, SIGH'
Tidal Volume10 ml ~ 300 ml'
Standard Ventilation ModeCMV, IMV, CPAP, Manual'
Tidal Volume20 ml ─ 2500 ml'
ConfigurationsTrolley or Ceiling Pendant'
Tidal Volume0 ml – 1500 ml'
Gas SupplyO<sub>2</sub>, 0.28 to 0.6 MPa'
Temperature Range37°C to 42°C'
Temperature Accuracy± 1.0°C'
Temperature Range37°C to 42°C'
Temperature Accuracy± 0.5°C'
TypeNeonatal'
Stroke volume150 ml'
TypePediatric'
Stroke volume350 ml'
TypeAdult'
Stroke volume800 ml'