Syringe pump KSP–B100

Syringe pump KSP–B100

Syringe pump KSP–B100 is a dual-channel light–weight, infusion device designed for low volume infusion. Equipped with separate LCD screen to display independent flow parameters. Inbuilt software system accurately delivers infusion rate and monitors infusion therapy. Memory log system stores last setting of infusion parameters for fast infusion.

Download Catalog
Channel Dual channel infusion
Volume (VTBI) 0.1 ml – 1999.9 ml
Injection Compliance Adaptable for 10 syringe sizes
Accuracy ≤ ± 3 %
KVO Rate 0.1 ml/h – 5 ml/h (steps : 0.1 ml/h)
Occlusion System 3 selectable occlusion levels
Infusion Rate 0.1 ml/h ~ 1600 ml/h, increment 0.1ml/h
Syringe Size Channel 01 : 5 ml / 10 ml / 20ml / 30ml / 50ml
Channel 02 : 6 ml / 12 ml / 25 ml / 35 ml / 60 ml
Bolus Syringe 50 ml: 1600 ml/h
Syringe 30 ml: 900 ml/h
Syringe 20 ml: 600 ml/h
Syringe 10 ml: 400 ml/h
Syringe 5 ml: 200 ml/h
Occlusion Alarm Threshold High: 110 kPa ± 20 kPa (825 mmHg ± 150 mmHg)
Medium: 80 kPa ± 30 kPa (600 mmHg ± 225 mmHg)
Low: 60 kPa ± 20 kPa (450 mmHg ± 150 mmHg)
Display 4.3” color segment LCD screen
Environmental conditions : Operation Ambient Temperature: 5 °C to 40 °C
Relative Humidity: 20 % to 90 %
Atmospheric Pressure: 86 kPa to 106 kPa
Environmental conditions : Storage Ambient Temperature: –30 °C to 55 °C
Relative Humidity: ≤  95%
Atmospheric Pressure: 50 kPa – 106 kPa
Alarm Occlusion, nearly finish, finish, standby (no operation),
low battery, battery exhausted 
Power Supply 100 V ~ 240 V, 50 Hz / 60 Hz
Power Consumption ≤ 25 VA
Safety Class I Type CF
Dimensions 354 × 132 × 199 mm
Weight 2.8 kg
  • Multi injection modes – Volume/Time/Body Adjustable speed, time, volume and dosage Audio–visual alarms with repeat alarm function Large data storage

Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.

Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.

Infant Incubator

Infant Incubator KII-A100

Infant Incubator KII-A100

Control SystemAir-temp control, Skin-temp control & Humidity control'

DisplayLED display'

Catalog
Infant Incubator KII-A101

Infant Incubator KII-A101

Control SystemAir-temp control & Skin-temp control'

DisplayLED display'

Catalog
Infant Incubator KII-A102
Infant Incubator KII-A102

Control SystemAir-temp control'

DisplayLED display'

Catalog

Infant Warmer

Infant Warmer KIW-A100

Infant Warmer KIW-A100

Control SystemMicroprocessor based temperature control system'

Control ModesPreheat, Manual and Skin-temp mode'

Catalog

Phototherapy Unit

LED Phototherapy System KPT-A100

LED Phototherapy System KPT-A100

Light Source8 Blue LED lights'

Wavelength450 to 475nm'

Catalog

Defibrillator

Defibrillator Monitor KDM-A100

Defibrillator Monitor KDM-A100

Display7-inch screen'

WaveformBiphasic'

Catalog
Automated External Defibrillator KED-A100

Automated External Defibrillator KED-A100

WaveformBiphasic'

Energy Sequence150 J, 200 J'

Catalog

Infusion Pump

Infusion Pump KIP–A100

Infusion Pump KIP–A100

ChannelSingle channel infusion'

Volume (VTBI)1 ml ~ 9999.9 ml ( 0.1 ml increment)'

Catalog
Infusion Pump KIP–A101

Infusion Pump KIP–A101

ChannelSingle channel infusion'

Infusion Volume0 ml ~ 9999 ml ( 0.1ml increment)'

Catalog

Ventilator

Intensive Care Ventilator KIV-A102

Intensive Care Ventilator KIV-A102

Tidal Volume10 ml ~ 300 ml'

Standard Ventilation ModeCMV, IMV, CPAP, Manual'

Catalog
Intensive-Care Ventilator KIV-A200

Intensive-Care Ventilator KIV-A200

Tidal Volume20 ml ─ 2500 ml'

ConfigurationsTrolley or Ceiling Pendant'

Catalog
Transport Ventilator KTV-A100
Transport Ventilator KTV-A100

Tidal Volume0 ml – 1500 ml'

Gas SupplyO<sub>2</sub>, 0.28 to 0.6 MPa'

Catalog
Intensive Care Ventilator KIV-A101
Intensive Care Ventilator KIV-A101

Tidal Volume20 ml ~ 500 ml'

Standard Ventilation ModeVCV, SIMV, PSV, PCV, CPAP, Manual, SIGH'

Catalog

Blood and Infusion Warmer

Blood and Infusion Warmer KBIW-A100

Blood and Infusion Warmer KBIW-A100

Temperature Range37°C to 42°C'

Temperature Accuracy± 0.5°C'

Catalog
Blood and Infusion Warmer KBIW-A200

Blood and Infusion Warmer KBIW-A200

Temperature Range37°C to 42°C'

Temperature Accuracy± 1.0°C'

Catalog

Resuscitator

Resuscitator KRE-A100

Resuscitator KRE-A100

TypeAdult'

Stroke volume800 ml'

Catalog
Resuscitator KRE-A101

Resuscitator KRE-A101

TypePediatric'

Stroke volume350 ml'

Catalog
Resuscitator KRE-A102
Resuscitator KRE-A102

TypeNeonatal'

Stroke volume150 ml'

Catalog