Infusion Pump KIP–A100 is a single-channel light–weight, drip-type volumetric fluid delivery system. Digitally driven fluid-control, automated calibration and dose titration enhances safety. Peristaltic pumping mechanism ensures precise flow-measurement and prevents back-flow of IV fluid. Backlit display enables suitably ambient illumination to operate even at low light condition.
| Channel | Single channel infusion | 
| Volume (VTBI) | 1 ml ~ 9999.9 ml ( 0.1 ml increment) | 
| Accuracy | Flow rate: ≤ ± 3 % Mechanical: ≤ ± 2 % | 
| KVO Rate | 1 ml/h (1 ml/h ~ 300 ml/h) 3 ml/h (greater than 300 ml/h) | 
| Occlusion System | 3 selectable occlusion levels | 
| Drop Rate | 1 drop/min ~ 400 drops/min (1 drop/min increment) | 
| Infusion Rate | 1.0 ml/h ~99.9 ml/h (0.1 ml/h increment) 100 ml/h ~1200 ml/h (1 ml/h increment) | 
| Purge | 800 ml/h | 
| Bolus | 10 ml/h ~ 1200 ml/h at 0.1 ml/h (flow rate < 100 ml/h) 10 ml/h ~ 1200 ml/h at 1 ml/h (flow rate > 100 ml/h) | 
| Therapy Timer Range | 1 min ~ 9999 min ( 1 min increment) | 
| Display | 4.3-inch colour LCD with backlight | 
| Drug Library | Database of up to 210 drugs | 
| Memory | Up to 1500 record entries | 
| Occlusion Threshold | High: 800 mmHg ± 200 mmHg (106.7 kPa ± 26.7 kPa) Medium: 500 mmHg ± 100 mmHg (66.7 kPa ± 13.3 kPa) Low: 300 mmHg ± 100 mmHg (40.7 kPa ± 13.3 kPa) | 
| Sensitivity [Bubble detection] | > 25 μL | 
| Environmental Condition : Operation | Operating temperature 5 ⁰C ~ 40 ⁰C Operating humidity 20 % ~ 90 % | 
| Environmental Condition: Storage | Storage temperature -10 ⁰C ~ 55 ⁰C Storage humidity 10 % ~ 90 % | 
| Fuse | F1AL / 250 V | 
| Power Supply | AC 85 ~ 265 V, 50/60 Hz, < 40 VA | 
| Battery | 11.1 V rechargeable Li-ion battery; > 2000 mAh Works more than 4 hours at 25 ml/h after charging for 8 hours | 
| Dimensions | 188 x 198 x 228 mm | 
| Weight | 2.5 Kgs | 
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Control SystemAir-temp control, Skin-temp control & Humidity control'
DisplayLED display'
Control SystemAir-temp control & Skin-temp control'
DisplayLED display'
Control SystemAir-temp control'
DisplayLED display'
Control SystemMicroprocessor based temperature control system'
Control ModesPreheat, Manual and Skin-temp mode'
Light Source8 Blue LED lights'
Wavelength450 to 475nm'
Display7-inch screen'
WaveformBiphasic'
WaveformBiphasic'
Energy Sequence150 J, 200 J'
Tidal Volume0 ml – 1500 ml'
Gas SupplyO<sub>2</sub>, 0.28 to 0.6 MPa'
Tidal Volume10 ml ~ 300 ml'
Standard Ventilation ModeCMV, IMV, CPAP, Manual'
Tidal Volume20 ml ─ 2500 ml'
ConfigurationsTrolley or Ceiling Pendant'
Tidal Volume20 ml ~ 500 ml'
Standard Ventilation ModeVCV, SIMV, PSV, PCV, CPAP, Manual, SIGH'
ChannelDual channel infusion'
Volume (VTBI)0.1 ml – 1999.9 ml'
ChannelSingle channel infusion'
Volume (VTBI)0 ml – 9999 ml'
KVO Rate0.1 – 5ml/h (steps : 0.1ml/h)'
Injection ComplianceAdaptable for 5 syringe sizes'
Temperature Range37°C to 42°C'
Temperature Accuracy± 1.0°C'
Temperature Range37°C to 42°C'
Temperature Accuracy± 0.5°C'
TypeAdult'
Stroke volume800 ml'
TypeNeonatal'
Stroke volume150 ml'
TypePediatric'
Stroke volume350 ml'