Syringe pump KSP–A200 is a single-channel light–weight, infusion system designed for low volume infusion. Programmed infusion modes, administer drug volume at specified rate as per patient dosage. Dose titration allows uninterrupted flow during change of flow rate. Real-time pressure sensing with anti-bolus and purge feature assures safe operation.
| Channel | Single channel infusion | 
| Volume (VTBI) | 0 ml – 9999 ml | 
| Injection Compliance | Adaptable for 6 syringe sizes | 
| Accuracy | ≤ ±2 % | 
| KVO Rate | 0.01 ml/h – 5 ml/h (steps : 0.01 ml/h) | 
| Occlusion System | 12 selectable occlusion levels | 
| Syringe Size | 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, 60 ml | 
| Infusion Mode | Rate mode/Time mode, Body weight, TIVA, Relay mode Loading-dose, Ramp up/down, Sequence, Drug library mode, Micro mode | 
| Flow Selection | 0.01 ml/h ~ 1500 ml/h, increment 0.01 ml/h | 
| Bolus Rate | 0.1 ml/h ~ 1500 ml/h (Auto or Manual bolus control) | 
| Display | 4.3-inch colour LCD screen | 
| Battery | Lithium polymer battery 11.1 V 2600 mAh About 12 hours of operation at 5ml/h (< 5 hours of charging) | 
| Memory | Records over 5000 entries for review | 
| Drug library | Database of up to 2000 drugs | 
| Safety | Class I Type CF | 
| Moisture Protection | IP24 | 
| Operation | Ambient Temperature: 5 °C to 40 °C Relative Humidity: 20 % to 90 % | 
| Storage | Ambient Temperature: –30 °C to 55 °C Relative Humidity: ≤ 95% | 
| Power Supply | AC : 110 V ~ 240 V, 50/60 Hz DC : 12 V | 
| Dimensions | 235 × 90 × 120 mm | 
| Weight | 1.7 kgs | 
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Control SystemAir-temp control, Skin-temp control & Humidity control'
DisplayLED display'
Control SystemAir-temp control'
DisplayLED display'
Control SystemAir-temp control & Skin-temp control'
DisplayLED display'
Control SystemMicroprocessor based temperature control system'
Control ModesPreheat, Manual and Skin-temp mode'
Light Source8 Blue LED lights'
Wavelength450 to 475nm'
WaveformBiphasic'
Energy Sequence150 J, 200 J'
Display7-inch screen'
WaveformBiphasic'
ChannelSingle channel infusion'
Infusion Volume0 ml ~ 9999 ml ( 0.1ml increment)'
ChannelSingle channel infusion'
Volume (VTBI)1 ml ~ 9999.9 ml ( 0.1 ml increment)'
Tidal Volume0 ml – 1500 ml'
Gas SupplyO<sub>2</sub>, 0.28 to 0.6 MPa'
Tidal Volume20 ml ~ 500 ml'
Standard Ventilation ModeVCV, SIMV, PSV, PCV, CPAP, Manual, SIGH'
Tidal Volume10 ml ~ 300 ml'
Standard Ventilation ModeCMV, IMV, CPAP, Manual'
Tidal Volume20 ml ─ 2500 ml'
ConfigurationsTrolley or Ceiling Pendant'
Temperature Range37°C to 42°C'
Temperature Accuracy± 1.0°C'
Temperature Range37°C to 42°C'
Temperature Accuracy± 0.5°C'
TypePediatric'
Stroke volume350 ml'
TypeNeonatal'
Stroke volume150 ml'
TypeAdult'
Stroke volume800 ml'