Defibrillator Monitor KDM-A100 is a biphasic life-support clinical defibrillator equipped with provisional core functionalities which include guided automatic as well as manual defibrillation modes, advanced ECG monitoring, SpO2 monitoring and analysis for predictive arrhythmia detection as well as thermal recorder. System features high resolution screen, touch-key panel to display and select various monitoring parameters with energy navigation knob and alarm.
| Display | 7-inch screen | 
| Waveform | Biphasic | 
| Manual with Sync mode | 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules | 
| AED mode | Auto analyze and charge x 3 with programmable auto energy level selection. | 
| Interpreted rhythms for AED | Ventricular fibrillation ≥ 200 µV Ventricular tachycardia ≥ 140 bpm QRS complex wave duration ≥ 140 ms | 
| Sweep Speed | 25 mm/s | 
| Electrode impedance range | 0 Ω – 250 Ω | 
| Analysis Time | Less than 7 seconds | 
| ECG Lead selection | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V | 
| ECG Heart rate | 20 bpm – 300 bpm | 
| ECG size | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV | 
| ECG Heart Rate alarm | On / Off displayed on monitor, user-selectable | 
| SpO<sub>2</sub>measurement | 30 % – 100 % | 
| Recorder Paper Speed | 12.5 mm/s, 25 mm/s, 50 mm/s | 
| Alarm accuracy | ±10 % (less than 12 sec) | 
| Print modes | Manual or automatic, user-configurable | 
| Battery | Rechargeable, Ni-MH battery, 12V | 
| Dimensions | 500 x 380 x 360 mm | 
| Weight | 8 Kgs | 
Used in hospital emergency wards, OT, crash-cart throughout the hospital premises, primary healthcare centers and rescue ambulance to deliver counter-shocks during sudden cardiac arrest or cardiac resuscitation situations.
Used in hospital emergency wards, OT, crash-cart throughout the hospital premises, primary healthcare centers and rescue ambulance to deliver counter-shocks during sudden cardiac arrest or cardiac resuscitation situations.
Control SystemAir-temp control & Skin-temp control'
DisplayLED display'
Control SystemAir-temp control'
DisplayLED display'
Control SystemAir-temp control, Skin-temp control & Humidity control'
DisplayLED display'
Control SystemMicroprocessor based temperature control system'
Control ModesPreheat, Manual and Skin-temp mode'
Light Source8 Blue LED lights'
Wavelength450 to 475nm'
ChannelSingle channel infusion'
Volume (VTBI)1 ml ~ 9999.9 ml ( 0.1 ml increment)'
ChannelSingle channel infusion'
Infusion Volume0 ml ~ 9999 ml ( 0.1ml increment)'
Tidal Volume0 ml – 1500 ml'
Gas SupplyO<sub>2</sub>, 0.28 to 0.6 MPa'
Tidal Volume10 ml ~ 300 ml'
Standard Ventilation ModeCMV, IMV, CPAP, Manual'
Tidal Volume20 ml ─ 2500 ml'
ConfigurationsTrolley or Ceiling Pendant'
Tidal Volume20 ml ~ 500 ml'
Standard Ventilation ModeVCV, SIMV, PSV, PCV, CPAP, Manual, SIGH'
KVO Rate0.1 – 5ml/h (steps : 0.1ml/h)'
Injection ComplianceAdaptable for 5 syringe sizes'
ChannelDual channel infusion'
Volume (VTBI)0.1 ml – 1999.9 ml'
ChannelSingle channel infusion'
Volume (VTBI)0 ml – 9999 ml'
Temperature Range37°C to 42°C'
Temperature Accuracy± 1.0°C'
Temperature Range37°C to 42°C'
Temperature Accuracy± 0.5°C'
TypeAdult'
Stroke volume800 ml'
TypePediatric'
Stroke volume350 ml'
TypeNeonatal'
Stroke volume150 ml'