Infusion Pump KIP–A101 is a single-channel light–weight, drip-type volumetric fluid delivery system. Built-in pressure sensor system reduces false alarm. Infusion driver accurately delivers infusion rate and monitors infusion therapy. Backlit display enables suitably ambient illumination to operate even at low light condition. Smooth dustproof exterior design allows easy maintenance.
| Channel | Single channel infusion | 
| Infusion Volume | 0 ml ~ 9999 ml ( 0.1ml increment) | 
| Infusion Rate | 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment) | 
| KVO Rate | 0.01 ml/h – 5 ml/h | 
| Occlusion | 4 selectable levels of occlusion | 
| Accuracy | ±5% | 
| Infusion Modes | Rate mode, Time mode, Body weight, Drip mode, Micro mode | 
| Drop Rate | 1 drop/min ~ 400 drops/min (1 drop/min increment) | 
| Purge | Available | 
| Bolus | 0.1 ml/h ~1200 ml/h (auto & manual bolus control) | 
| Therapy Timer Range | 1 min ~ 9999 min ( 1 min increment) | 
| Display | 4.3-inch colour LCD with backlight | 
| Drug Library | Database of up to 30 drugs | 
| Memory | Up to 5000 record entries | 
| Safety | Class I, CF | 
| Moisture Protection | IP24 | 
| Stand by | 00 mins – 99 h 59 mins | 
| Free-flow Protection | Anti-free flow safeguard clip lock system | 
| Power Supply | AC: 110 V ~ 240 V, 50 Hz / 60 Hz, DC: 12 V | 
| Battery | 11.1 V rechargeable Li-ion battery; > 2600 mAh Works more than 9 hours at 25 ml/h after charging for 5 hours | 
| Dimensions | 235 x 95 x 120 mm | 
| Weight | 1.6 Kg | 
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Control SystemAir-temp control & Skin-temp control'
DisplayLED display'
Control SystemAir-temp control, Skin-temp control & Humidity control'
DisplayLED display'
Control SystemAir-temp control'
DisplayLED display'
Control SystemMicroprocessor based temperature control system'
Control ModesPreheat, Manual and Skin-temp mode'
Light Source8 Blue LED lights'
Wavelength450 to 475nm'
Display7-inch screen'
WaveformBiphasic'
WaveformBiphasic'
Energy Sequence150 J, 200 J'
Tidal Volume20 ml ─ 2500 ml'
ConfigurationsTrolley or Ceiling Pendant'
Tidal Volume10 ml ~ 300 ml'
Standard Ventilation ModeCMV, IMV, CPAP, Manual'
Tidal Volume0 ml – 1500 ml'
Gas SupplyO<sub>2</sub>, 0.28 to 0.6 MPa'
Tidal Volume20 ml ~ 500 ml'
Standard Ventilation ModeVCV, SIMV, PSV, PCV, CPAP, Manual, SIGH'
KVO Rate0.1 – 5ml/h (steps : 0.1ml/h)'
Injection ComplianceAdaptable for 5 syringe sizes'
ChannelSingle channel infusion'
Volume (VTBI)0 ml – 9999 ml'
ChannelDual channel infusion'
Volume (VTBI)0.1 ml – 1999.9 ml'
Temperature Range37°C to 42°C'
Temperature Accuracy± 0.5°C'
Temperature Range37°C to 42°C'
Temperature Accuracy± 1.0°C'
TypePediatric'
Stroke volume350 ml'
TypeNeonatal'
Stroke volume150 ml'
TypeAdult'
Stroke volume800 ml'