KSPM-A100 is a hand held unit which can be used in two different ways (connectible to PC through USB or the unit itself as a desktop) to meet user’s requirements. It features a large TFT screen to display measured FVC, FEV and PEF values. It displays volume and flow rate charts to support diagnosis. Automated unit shut down in case of no user operation.
| Flow range | 1 L/s ⁓ 16 L/s |
| Volume range | 10 L |
| Flow accuracy | ± 10 % |
| Volume Accuracy | ± 3 % |
| Trend |
Flow rate – Volume Volume – time |
| Measure mode | Infrared |
| Measures |
FVC - Forced Vital Capacity FEV - Forced Expired Volume in one second PEF - Peak expiratory flow |
| Operating environment |
Temperature: +10 °C ~ +40 °C Relative humidity: ≤80 % Atmospheric pressure: 70 kPa~106 kPa |
| Storage environment |
Temperature: -40 °C ~ +55 °C Relative humidity: ≤ 95 % Atmospheric pressure: 50 kPa~106 kPa |
| Working Current | 60 mA |
| Battery | DC 3.7 V ; 820 mAh |
| Dimension | 97 × 89 × 36 mm |
| Weight | 150 g |
Used to check lung conditions to diagnose chronic respiratory diseases. Applicable for routine analysis in hospital, clinics.
Used to check lung conditions to diagnose chronic respiratory diseases. Applicable for routine analysis in hospital, clinics.
Exposure Voltage50 kV ~ 100 kV'
Exposure CurrentSmall focus: 50 mA </br> Big focus: (50, 100, 150 and 200) mA'
Exposure Voltage50 kV ~ 125 kV'
Exposure CurrentSmall focus: (50, 100) mA </br> Big focus: (50, 100, 200 and 300) mA'
Inverter Frequency50 kHz'
Tube Voltage40 kV – 120 kV (interval 1 kV)'
Exposure Voltage50 kV ~ 90 kV'
Exposure CurrentSmall focus: 25 mA </br> Big focus: (50, 75, 100 and 125) mA'
Inverter Frequency50 kHz'
Tube Voltage40 kV – 100 kV (interval 1 kV)'
Inverter Frequency50 kHz'
Tube Voltage40 kV – 120 kV (interval 1 kV)'
Focal Distance 350 x 350 mm'
Source Head Range520 mm - 1880 mm'
Focal Distance430 × 430 mm'
Source Head Range550 mm - 1820 mm'
Max Output Power4 kW'
Nominal Power100 kV, 40mA, 0.1 s, 4 kW'
Generator TypeHigh frequency inverter 80 kHz'
Radiographic RatingsLarge focal point, 20-35 kV/10-510 mAs <br/> Small focal point, 20-35 kV/ 10-110 mAs'
Generator TypeHigh frequency inverter 40 kHz'
Radiographic RatingsLarge focal point, 20-35 kV/10-510 mAs <br/> Small focal point, 20-35 kV/ 10-110 mAs'
Display Size12” Color LCD Triplex display'
Display ModesB/BB/B/M/CD/PWD/CWD/DIR PWR/PWR'
Display Size10-inch screen'
Display Depth≥ 250 mm'
Display Size10-inch screen'
Display Depth≥ 250 mm'
Display Size12-inch LCD screen'
Display Depth40mm to 250 mm'
Display size15-inch LCD screen'
Display depth250 mm'
Display size15-inch LCD screen'
Display depth250 mm'
No. of Channels10'
No. of Sample Analysis5'
Tube Voltage60 kV'
Tube Current1 mA'
Tube Voltage60 kV'
Tube Current8 mA'
Tube Voltage60 kV'
Tube Current8 mA'
Tube Voltage90 kVp'
Tube Current10 mA'
Image Sensor1/4″ Super HAD color CCD'
CCD Resolution (HD optional)8,00,000 pixels'
Display3” TFT panel, 4:3 ratio'
MagnificationOptical : 20-200 X </br> Digital : 500 X'
LCD Display6” Real-time display'
Expandable StorageUp to 1008 ECGs'
LCD Display6” LCD real-time'
Expandable StorageUp to 250 ECGs'
LCD Display3.8 inch Graphic'
Expandable StorageUp to 250 ECGs'
LCD Display192 x 64 Graphic'
Expandable Storage'
Number of channels4 channel'
Stimulus ModesSingle-current, Dual-current Stimulator'
TypeTwo-channel for independent outputs'
Test SignalPure tone, Pulse tone, Warble tone, Narrowband noise'
BulbOne spare bulb'
Bulb typeStainless bulb'
Light sourceLED bulb'
LuminanceAbout 18.5 lumen'
Otoscope1'
Size ear speculum3'
Input channel(12/24/36/48 Monopolar EEG+12channelsBipolar EEG+12channels PSG)'
Recording modesReal-time'
Input channel(19 Monopolar EEG and 1 Bipolar ECG)'
Recording modesReal-time (via Bluetooth) / Dynamic (via Flash memory)'
Input channel32/64/128 channels Monopolar EEG'
Recording modesReal-time'
Range of measurement<table class="tableizer-table"> <thead><tr class="tableizer-firstrow"><th>Lens</th><th>Range</th></tr></thead><tbody> <tr><td>Sphere</td><td>-25 ~ +25 D unit( 0.01/0.12/0.25 D steps)</td></tr> <tr><td>Cylinder</td><td>-9.99 ~ +9.99 D unit (0.01/0.12/0.25 D steps)</td></tr> <tr><td>Axis</td><td>0° ~ 180° unit (1° steps)</td></tr> <tr><td>Add</td><td>0 ~ +9.99 D unit (0.01/0.12/0.25 D)</td></tr> <tr><td>Prism</td><td>0 ~ 6 △ unit ( 0.01/0.12/0.25 △)</td></tr> </tbody></table>'
Lens measurement type<table class="tableizer-table"> <thead><tr class="tableizer-firstrow"><th>Lens</th><th>Type</th></tr></thead><tbody> <tr><td>Cylinder</td><td> +,+/-,-</td></tr> <tr><td>Prism</td><td> X-Y,P-B</td></tr> <tr><td>Contact lens </td><td> Soft/hard</td></tr> </tbody></table>'