Electromyography KEMG-A100 is a 4-channel digital neurophysiological EMG/EP recording unit. System utilizes stimulator-coupled amplifier for compact system assembly. Functional electric stimulator generates single and dual current stimulation for optimal diagnostic evaluation of the condition.
| Number of channels | 4 channel |
| Stimulus Modes | Single-current, Dual-current Stimulator |
| Stimulus Frequency | 0.1 Hz ~ 50 Hz |
| Sample Rate | 200 KHz |
| Analysis Time | 1 ms ~ 1000 ms |
| CMRR | >110 dB |
| Amplitude Frequency | 1 Hz ~ 5 Hz |
| Impedance | > 1000 MΩ |
| 0.1 H7:I23⁓ 100 Hz, Error <± 10% | 1 ~ 5000 times |
| Test Protocols : EMG | Motor Unit Potential (MUP) Interference phase (IP) Scanning EMG (QEMG) |
| Test Protocols : EP | SEP : USEP / LESEP / TSEP / SCEP AEP : BAEP / MAEP / LAEP / Eooch G, 40Hz VEP : PRVEP / FVEP / ERG / EOG |
| Test Protocols : NCV | MCV / SCV / SSCT / RNS / F-wave / H-reflex / Blink reflex / SSR |
| Max Higher Filters Frequency | 50 Hz |
| Min Lower Filters Frequency | 0.1 Hz |
| A/D Conversion Rate | 24 bit |
| Stimulus Width | 0.1 ⁓ 100 Hz, Error <± 10% |
| Pulse Mode | 50 µs ~ 1000 µs |
| Pulse Duration Error | Single, Double and Triple pulses |
| Gain Amplifier | 0.05, 0.1, 0.5, 1 ms , Error <± 10% |
| Dimensions | 50 times ⁓ 50 million times |
| Weight | 510 x 445 x 205 mm |
Used in OPD, neurology departments to detect musculature or sensory abnormalities, muscle activation level or to analyze any gait or biomechanics application.
| Sr | Standard Accessories | Qty |
|---|---|---|
| 1 | Saddle Electrode ( Bar type) | 1 pc |
| 2 | Saddle Electrode ( Felt type) | 1 pc |
| 3 | Ring Electrode | 1 pc |
| 4 | Band Electrode(long) | 1 pc |
| 5 | Band Electrode(short) | 1 pc |
| 6 | Adhensive electrode(disposable) | 40 pcs |
| 7 | Concentric needle electrode【small】 | 1 pc |
| 8 | Concentric needle electrode【medium】 | 4 pcs |
| 9 | Concentric needle electrode【large】 | 1 pc |
Used in OPD, neurology departments to detect musculature or sensory abnormalities, muscle activation level or to analyze any gait or biomechanics application.
Exposure Voltage50 kV ~ 125 kV'
Exposure CurrentSmall focus: (50, 100) mA </br> Big focus: (50, 100, 200 and 300) mA'
Max Output Power4 kW'
Nominal Power100 kV, 40mA, 0.1 s, 4 kW'
Focal Distance 350 x 350 mm'
Source Head Range520 mm - 1880 mm'
Inverter Frequency50 kHz'
Tube Voltage40 kV – 100 kV (interval 1 kV)'
Inverter Frequency50 kHz'
Tube Voltage40 kV – 120 kV (interval 1 kV)'
Exposure Voltage50 kV ~ 100 kV'
Exposure CurrentSmall focus: 50 mA </br> Big focus: (50, 100, 150 and 200) mA'
Inverter Frequency50 kHz'
Tube Voltage40 kV – 120 kV (interval 1 kV)'
Exposure Voltage50 kV ~ 90 kV'
Exposure CurrentSmall focus: 25 mA </br> Big focus: (50, 75, 100 and 125) mA'
Focal Distance430 × 430 mm'
Source Head Range550 mm - 1820 mm'
Generator TypeHigh frequency inverter 80 kHz'
Radiographic RatingsLarge focal point, 20-35 kV/10-510 mAs <br/> Small focal point, 20-35 kV/ 10-110 mAs'
Generator TypeHigh frequency inverter 40 kHz'
Radiographic RatingsLarge focal point, 20-35 kV/10-510 mAs <br/> Small focal point, 20-35 kV/ 10-110 mAs'
Display Size10-inch screen'
Display Depth≥ 250 mm'
Display Size12-inch LCD screen'
Display Depth40mm to 250 mm'
Display size15-inch LCD screen'
Display depth250 mm'
Display Size12” Color LCD Triplex display'
Display ModesB/BB/B/M/CD/PWD/CWD/DIR PWR/PWR'
Display Size10-inch screen'
Display Depth≥ 250 mm'
Display size15-inch LCD screen'
Display depth250 mm'
No. of Channels10'
No. of Sample Analysis5'
Tube Voltage60 kV'
Tube Current8 mA'
Tube Voltage90 kVp'
Tube Current10 mA'
Tube Voltage60 kV'
Tube Current8 mA'
Tube Voltage60 kV'
Tube Current1 mA'
Image Sensor1/4″ Super HAD color CCD'
CCD Resolution (HD optional)8,00,000 pixels'
Display3” TFT panel, 4:3 ratio'
MagnificationOptical : 20-200 X </br> Digital : 500 X'
LCD Display192 x 64 Graphic'
Expandable Storage'
LCD Display6” Real-time display'
Expandable StorageUp to 1008 ECGs'
LCD Display3.8 inch Graphic'
Expandable StorageUp to 250 ECGs'
LCD Display6” LCD real-time'
Expandable StorageUp to 250 ECGs'
Otoscope1'
Size ear speculum3'
Light sourceLED bulb'
LuminanceAbout 18.5 lumen'
TypeTwo-channel for independent outputs'
Test SignalPure tone, Pulse tone, Warble tone, Narrowband noise'
BulbOne spare bulb'
Bulb typeStainless bulb'
Flow range1 L/s ⁓ 16 L/s'
Volume range10 L'
Input channel(19 Monopolar EEG and 1 Bipolar ECG)'
Recording modesReal-time (via Bluetooth) / Dynamic (via Flash memory)'
Input channel32/64/128 channels Monopolar EEG'
Recording modesReal-time'
Input channel(12/24/36/48 Monopolar EEG+12channelsBipolar EEG+12channels PSG)'
Recording modesReal-time'
Range of measurement<table class="tableizer-table"> <thead><tr class="tableizer-firstrow"><th>Lens</th><th>Range</th></tr></thead><tbody> <tr><td>Sphere</td><td>-25 ~ +25 D unit( 0.01/0.12/0.25 D steps)</td></tr> <tr><td>Cylinder</td><td>-9.99 ~ +9.99 D unit (0.01/0.12/0.25 D steps)</td></tr> <tr><td>Axis</td><td>0° ~ 180° unit (1° steps)</td></tr> <tr><td>Add</td><td>0 ~ +9.99 D unit (0.01/0.12/0.25 D)</td></tr> <tr><td>Prism</td><td>0 ~ 6 △ unit ( 0.01/0.12/0.25 △)</td></tr> </tbody></table>'
Lens measurement type<table class="tableizer-table"> <thead><tr class="tableizer-firstrow"><th>Lens</th><th>Type</th></tr></thead><tbody> <tr><td>Cylinder</td><td> +,+/-,-</td></tr> <tr><td>Prism</td><td> X-Y,P-B</td></tr> <tr><td>Contact lens </td><td> Soft/hard</td></tr> </tbody></table>'