Surgical Diathermy Machine KSD-A100

Surgical Diathermy Machine KSD-A100

Surgical Diathermy Machine KSD-A100 is a table-top 350 W RF electrosurgical generator which modulates frequency levels to achieve Pure-cut, 2 variations of Blend, 3 variations of Coagulation and 2 variations in bipolar mode for a smooth cut at minimum tissue damage and effective incision without blood loss. Integrated powerful high frequency generator based control system equipped with smart resistance feedback and automatic output compensation designed to operate as per programmed output modes.

Download Catalog
Power Consumption 350 W
Operating Frequency 330 kHz ─ 460 kHz
Modes 6 Monopolar modes
2 Bipolar modes
Monopolar Cut : Pure Cut 1 W ─ 350 W at 500 Ω load impedance
Monopolar Cut : Blend I 1 W ─ 250 W at 500 Ω load impedance
Monopolar Cut : Blend II 1 W ─ 150 W at 500 Ω load impedance
Monopolar Coagulation : Coag I 1 W ─ 120 W at 500 Ω load impedance
Monopolar Coagulation : Coag II 1 W ─ 100 W at 500 Ω load impedance
Monopolar Coagulation : Coag III 1 W ─ 50 W at 500 Ω load impedance
Bipolar I 1 W ─ 150 W at 100 Ω load impedance
Bipolar II 1 W ─ 100 W at 100 Ω load impedance
Memory Functions 10 Memory programs
Pressure Range 50 kPa ─ 106 kPa
Relative Humidity Range ≤ 80%
Operating Temperature 10 °C ─ 40 °C
Power Supply 220 V ─ 110 V 50/60 Hz
Dimensions 430 x 380 x 165 mm
Weight 7 Kgs
  • 3 monopolar cut modes 3 monopolar coagulation modes Bipolar vessel sealing mode Bipolar coagulation mode Auto-test at power-up Excellent compatibility with various endoscopy sub-units 10 memory settings with memory back-up Alarm for Improper or Inadequate electrode contact

Used in surgical rooms, OTs for microsurgery, neurosurgery, laparoscopy and other surgeries to make precise cuts with limited blood loss for safe and effective hemostasis during cutaneous incision.

SrAccessoriesQty
1Disposable ESU pencil5
2ESU split pad5
3Reusable Silicon pad with cable1
4Reusable Cable for disposable pad1
5Reusable ESU pencil1
6Reusable Bipolar forceps with Cable1
7Power Cord1
8Dual pedal Switch 1
9Individual pedal Switch1
10Disposable short-tip electrode10
11Disposable long-tip electrode10

Used in surgical rooms, OTs for microsurgery, neurosurgery, laparoscopy and other surgeries to make precise cuts with limited blood loss for safe and effective hemostasis during cutaneous incision.

Anaesthesia System

Anaesthesia System KAM-A102

Anaesthesia System KAM-A102

DriveElectronically controlled, pneumatic driven'

Tidal Volume20 ml – 1500 ml'

Catalog
Anaesthesia System KAM-A100

Anaesthesia System KAM-A100

DriveElectronically controlled, pneumatic driven'

Tidal Volume0 ml -1500 ml'

Catalog
Anaesthesia System KAM-A200
Anaesthesia System KAM-A200

DriveElectronically controlled, pneumatic driven'

Tidal Volume0 ml ~ 1500 ml'

Catalog
Anaesthesia System KAM-A101
Anaesthesia System KAM-A101

DriveElectronically controlled, bellow driven'

Tidal Volume0 ml – 1500 ml'

Catalog
Anaesthesia System KAM-B100

Anaesthesia System KAM-B100

Ventilation ModesIPPV, PCV, SIMV + PS, PS and Manual'

Tidal Volume20 ml to 1500 ml'

Catalog

C-Arm X-ray Imaging

Mobile C-Arm X-ray KCX-A100

Mobile C-Arm X-ray KCX-A100

X-Ray GeneratorFrequency 40 kHz </br> Power Capacity 3.5 kW'

Tube CurrentX-ray : 20 mA - 63 mA </br> Fluoroscopy : 8 mA'

Catalog